systemd.kill — Process killing procedure configuration
,
service
.service
,
socket
.socket
,
mount
.mount
,
swap
.swapscope
.scope
Unit configuration files for services, sockets, mount points, swap devices and scopes share a subset of configuration options which define the killing procedure of processes belonging to the unit.
This man page lists the configuration options shared by these five unit types. See systemd.unit(5) for the common options shared by all unit configuration files, and systemd.service(5), systemd.socket(5), systemd.swap(5), systemd.mount(5) and systemd.scope(5) for more information on the configuration file options specific to each unit type.
The kill procedure configuration options are configured in the [Service], [Socket], [Mount] or [Swap] section, depending on the unit type.
KillMode=
¶Specifies how processes of this unit shall be
killed. One of
control-group
,
process
,
mixed
,
none
.
If set to control-group
, all remaining
processes in the control group of this unit will be killed on
unit stop (for services: after the stop command is executed,
as configured with ExecStop=
). If set to
process
, only the main process itself is
killed. If set to mixed
, the
SIGTERM
signal (see below) is sent to the
main process while the subsequent SIGKILL
signal (see below) is sent to all remaining processes of the
unit's control group. If set to none
, no
process is killed. In this case, only the stop command will be
executed on unit stop, but no process be killed otherwise.
Processes remaining alive after stop are left in their control
group and the control group continues to exist after stop
unless it is empty.
Processes will first be terminated via
SIGTERM
(unless the signal to send is
changed via KillSignal=
). Optionally, this
is immediately followed by a SIGHUP
(if
enabled with SendSIGHUP=
). If then, after a
delay (configured via the TimeoutStopSec=
option), processes still remain, the termination request is
repeated with the SIGKILL
signal (unless
this is disabled via the SendSIGKILL=
option). See
kill(2)
for more information.
Defaults to
control-group
.
KillSignal=
¶Specifies which signal to use when killing a
service. This controls the signal that is sent as first step
of shutting down a unit (see above), and is usually followed
by SIGKILL
(see above and below). For a
list of valid signals, see
signal(7).
Defaults to SIGTERM
.
Note that, right after sending the signal specified in
this setting, systemd will always send
SIGCONT
, to ensure that even suspended
tasks can be terminated cleanly.
SendSIGHUP=
¶Specifies whether to send
SIGHUP
to remaining processes immediately
after sending the signal configured with
KillSignal=
. This is useful to indicate to
shells and shell-like programs that their connection has been
severed. Takes a boolean value. Defaults to "no".
SendSIGKILL=
¶Specifies whether to send
SIGKILL
to remaining processes after a
timeout, if the normal shutdown procedure left processes of
the service around. Takes a boolean value. Defaults to "yes".